Description
Sikadur®-42 HF is a pourable, multi-functional high density epoxy grout based on a 2-component solvent free epoxy resin system containing fine fillers. Sikadur-42 HF exhibits excellent flow characteristics in general grouting applications.
USES
As a grout for manufacturing plants and civil engineering application:
- Crane rails
- Machine bedding and baseplates
- Holding down bolts
- Stanchions
- Starter bars
- Cavity filling
- Bridge bearings
CHARACERISTICS AND ADVANTAGES
- Cost effective epoxy grout
- Applicable at low temperatures.
- High mechanical strengths.
- High flow characteristics
- Supplied in factory proportioned units.
- Shrink free.
- Can be bulked out with aggregate of thicker pour applications
- Excellent chemical resistance to water, sea water, waste water, sewage, fuels, oils, dilute acids and dilute alkalis.
COLOUR
Mixed: Grey
PACKAGING
18 kg net pre-proportioned kit
SUBSTRATE QUALITY
Mortar and concrete must be older than 28 days (dependent on minimum strength requirements). Verify the substrate strength (concrete, natural stone etc.).
The substrate surface (all types) must be clean, dry and free from contaminants such as dirt, oil, grease,
existing surface treatments and coatings etc. Steel substrates must be de-rusted to a standard equivalent to Sa 2.5.
The substrate must be sound and all loose particles must be removed. Substrate must be dry or mat damp and free from any standing water, ice etc.
SUBSTRATE PREPARATION
Surface and base plate contact area must be clean and sound. For best results, the substrate should be dry. Remove dust, laitance, oils, grease, curing compounds, impregnations, waxes, foreign particles, coatings, and disintegrated materials by mechanical means, i.e. chipping
with a chisel, blastcleaning etc. All anchor pockets or sleeves must be free of water. Blastcleaning metal base plates to an acceptable quality standard equivalent to SA 2.5 for maximum adhesion. Apply grout immediately to prevent re-oxidizing.
Forming:
The consistency of the Sikadur®-42 HF epoxy grout system requires the use of permanent or temporary forms to contain the material around base plates, for example. In order to prevent leakage or seepage, all of these formers must be sealed. Apply polyethylene film or wax to all forms to prevent adhesion of the grout. Prepare the formwork to maintain more than 100 mm liquid head to facilitate placement. A grout box
equipped with an inclined trough attached to the form will enhance the grout flow and minimize air encapsulation.
MIXING
Prior to mixing the components should be stored at 15-20°C for the previous 24 hours. Mix all of component A (Grey Resin) with all of component B (Hardener) using a slow speed drill (maximum 600 rpm) and windmill stirrer. Mix until a homogeneous and streak free mixture results.
Sikadur 42 HF Data Sheets
Sikadur®-42HF – Sika’s Website
Reviews